Lenovo ThinkSystem SR665
Lenovo's 2-socket 2U rack server (machine types 7D2V/7D2W) for AMD EPYC 7002 "Rome" and 7003 "Milan"/"Milan-X" processors up to 64 cores and 280 W, with 32 DDR4-3200 DIMM slots (up to 8 TB), up to 40 x 2.5-inch or 20 x 3.5-inch drives across front, mid and rear bays, up to eight PCIe 4.0 slots plus OCP 3.0, and up to three double-wide GPUs. Aimed at virtualization, VDI, HPC, hyperconverged and inference workloads.
Memory
- Slots
- 32 DIMM (16 per processor; 8 channels per CPU, 2 DIMMs per channel)
- Types
- Lenovo TruDDR4 RDIMM (16, 32, 64 GB), 3DS RDIMM (128, 256 GB) and Performance+ RDIMM (32, 64 GB); no mixing of RDIMM with 3DS RDIMM, or Performance+ with standard DIMMs
- Speed
- RDIMM 3200 MHz at 1 DPC / 2933 MHz at 2 DPC; 3DS RDIMM 2933 / 2666 MHz; Performance+ RDIMM 3200 MHz at both 1 and 2 DPC
- Max
- 8 TB (32 x 256 GB 3DS RDIMM); 2 TB with one processor
- Population
- Best performance with 8 or 16 DIMMs per processor (all channels used); at most two DIMM capacities per processor
- Persistent memory
- Not supported
- Protection
- ECC, SDDC (x4 DIMMs), Patrol/Demand Scrubbing, DRAM Address Command Parity with Replay, DRAM Uncorrected ECC Error Retry, Post Package Repair; no mirroring or rank sparing
Storage
- Front 2.5"
- 8, 16 or 24 x 2.5" in SAS/SATA, NVMe and AnyBay combinations (8-bay backplanes: 8x SAS/SATA, 8x AnyBay, 8x NVMe)
- Front 3.5"
- 8 x 3.5" SAS/SATA, 12 x 3.5" SAS/SATA or 12 x 3.5" AnyBay
- Mid-chassis
- 4 x 3.5" SAS/SATA, 8 x 2.5" SAS/SATA or 8 x 2.5" NVMe (hot-swap, reached through the top cover; needs two CPUs and risers 1 and 2)
- Rear
- 2 or 4 x 3.5" SAS/SATA, or 4 or 8 x 2.5" SAS/SATA; plus 2 x 7mm SATA or NVMe (Marvell RAID) in place of slot 3 or slot 6
- NVMe
- Up to 16 NVMe drives direct 1:1, up to 32 with 1:2 oversubscription via NVMe switch adapters; up to 12 NVMe in 3.5" configurations
- Capacity
- Up to 1966.08 TB (32 x 61.44 TB NVMe SSD) or 440 TB (20 x 22 TB 3.5" HDD)
- Controllers
- Onboard SATA (up to 12 drives, JBOD only), onboard NVMe, 1610-8P / 1611-8P NVMe switch and 4-port retimer, RAID 530/540/930/940/5350/9350 8i-32i (940-32i up to 8 GB flash; 940 Tri-Mode for U.3), 430/440/4350 HBAs, 48-port internal SAS expander
- Internal RAID bay
- With 2.5" front bays, a cabled internal RAID 940-16i, 9350-8i/16i, 5350-8i or HBA 440-16i mounts behind the front bays without using a PCIe slot
- M.2 boot
- Internal M.2 module for 1 or 2 drives (on the air baffle, or on the mid-drive cage): SATA RAID (Marvell 88SE9230), NVMe RAID (Marvell 88NR2241) or SATA/NVMe non-RAID; 2242 to 22110
- Optical
- None internal; external USB DVD-RW option
Graphics
- Onboard
- Matrox G200 in the XClarity Controller, 16 MB, max 1920x1200 at 60 Hz
- Double-wide GPUs
- NVIDIA H100 80GB, L40 48GB, A100 80GB/40GB, A800 80GB (PRC), A40 48GB, A30 24GB, A16 64GB, Tesla V100S 32GB, V100 16GB, Quadro RTX 8000/6000 (special bid); up to 3 in slots 2, 5 and 7
- Single-wide GPUs
- NVIDIA L4, A2, T4, Quadro P620 (up to 8, slots 1-8); A10 24GB (up to 3, slots 1, 4, 7)
- Rules
- All GPUs identical; double-wide GPU blocks the adjacent slot 1, 4 or 8; no mid or rear drives with T4/V100/A100; only the P620 with 24 x 2.5" or 12 x 3.5" fronts; performance fans required, and since those fans were withdrawn GPUs can no longer be ordered CTO
Expansion
- Slots 1-3
- Riser 1 (CPU 1): PCIe 4.0 x16/x8/x8, x16/x16/empty, empty/x16/x16 or single x16; all full-height (PCIe 3.0 x16/x8/x8 riser also offered)
- Slots 4-6
- Riser 2 (CPU 2): same riser choices as riser 1, full-height
- Slots 7-8
- Riser 3 (cabled; slot 7 CPU 1, slot 8 CPU 2): PCIe 4.0 x16/x16 or x8/x8, full-height; mutually exclusive with onboard NVMe ports
- OCP
- Dedicated OCP 3.0 SFF slot, PCIe 4.0 x16
- Slot layouts
- 8 slots; 4 slots + 2 x 3.5" rear; 2 slots + 4 x 3.5" rear; 6 slots + 4 x 2.5" rear; 3 slots + 8 x 2.5" rear (7mm drives take one more slot)
- Internal
- Cabled PCIe 4.0 x8 connector for an internal RAID adapter/HBA (2.5" chassis only)
- Serial
- Optional DB-9 COM port bracket in slot 3 or slot 6
Networking
- OCP 3.0
- Optional 2- or 4-port adapters: 1 GbE (Broadcom 5719, Intel I350), 10GBASE-T (Broadcom 57416/57454, Intel X710-T2L/T4L, Marvell QL41132), 10/25 GbE SFP28 (Broadcom 57414/57454/57504, Intel E810-DA2/DA4, Marvell QL41232, Mellanox ConnectX-4 Lx / ConnectX-6 Lx); one port can be shared with the XCC
- PCIe
- 1/10/25 GbE, 100 GbE (Broadcom 57508, ConnectX-6 Dx), InfiniBand HDR100/HDR and NDR200/NDR 400 Gb (ConnectX-6, ConnectX-7), Xilinx Alveo U25/U50
- Fibre Channel
- Emulex LPe36002 64Gb, Emulex LPe35000/35002 32Gb, QLogic QLE2770/2772 32Gb, Emulex and QLogic 16Gb HBAs
- Management
- 1 x RJ-45 10/100/1000 Mb XClarity Controller port
Power
- PSU options
- 500 W, 750 W, 1100 W Platinum (115/230 V), 1800 W Platinum (230 V), 750 W, 1100 W, 1800 W, 2600 W Titanium (230 V), 1100 W -48 V DC
- Redundancy
- 1 or 2 hot-swap PSUs; both must be identical
- Connector
- C14 inlets on most AC units; the 2600 W Titanium uses C19-type cords; Weidmuller terminal on the -48 V DC unit
- Input current
- 100-127 V: 500 W 5.7 A, 750 W Platinum 8.4 A, 1100 W 12 A; 200-240 V: 500 W 2.7 A, 750 W 4.1 A, 1100 W 6 A, 1800 W 10 A
- Cooling
- 5 (one CPU) or 6 (two CPUs, or one CPU with mid/rear drives or riser 3) hot-swap 60 mm fans, N+1; standard single-rotor 17K RPM or performance dual-rotor 18K RPM; fans in each PSU
- Heat output
- 242 W (825 BTU/hr) minimum to 1675 W (5715 BTU/hr) maximum configuration
Ports
- Front
- 1 x USB 3.1 Gen 1, 1 x USB 2.0 (XClarity Controller management), external diagnostics handset port, optional VGA
- Rear
- 3 x USB 3.1 Gen 1, 1 x VGA, 1 x RJ-45 XCC management, NMI button; optional DB-9 serial (slot 3 or 6)
- Internal
- 1 x USB 3.2 Gen 1 (OS or licence key)
Physical
- Form factor
- 2U rack
- Dimensions
- 445 mm W x 87 mm H x 764 mm D (17.5 x 3.4 x 30.1 in); 482 mm across the rack flanges
- Weight
- Maximum 38.8 kg (85.5 lb)
- Machine types
- 7D2V (3-year warranty), 7D2W (1-year warranty)
- Environment
- ASHRAE A2 (10-35 C) for most configurations; A3/A4 only without GPUs, ConnectX-6, CPUs of 170 W or more, NVMe add-in cards or 128 GB+ 3DS RDIMMs
- Acoustics
- Idle 43 dBA typical; operating 46 dBA typical, 56 dBA storage-rich, 68 dBA GPU-rich
Management
- BMC
- Lenovo XClarity Controller (Pilot4 XE401, dual-core ARM Cortex A9); Standard, Advanced (remote KVM up to 1600x1200) or Enterprise (virtual media, boot capture)
- Interfaces
- IPMI 2.0 (IPMI-over-LAN off by default), SNMPv3, CIM-XML, REST, Redfish, HTML5 web UI; dedicated 1 GbE RJ-45 port, or NC-SI shared on an OCP port
- Software
- XClarity Provisioning Manager (F1), Administrator, Integrators, Essentials, Energy Manager, Capacity Planner; XClarity Mobile via the front USB management port
- Security
- TPM 2.0 (TPM 1.2 also with EPYC 7002; Nationz TPM 2.0 in China), AMD Platform Secure Boot, UEFI Secure Boot, Platform Firmware Resiliency (NIST SP 800-193), NIST SP 800-147B, intrusion switch, optional lockable bezel
- Local
- Front operator panel; optional pull-out Integrated Diagnostics Panel (LCD) on 8 or 16 x 2.5" fronts (CTO only); External Diagnostics Handset port; light path LEDs for CPUs, DIMMs, drives, fans and PSUs
- Announced
- Product guide first published 2020-05-05
- Withdrawn
- Withdrawn from marketing (Lenovo Press update of 2026-04-21)
Operating systems
- Windows
- Windows Server 2016, 2019, 2022; 2025 with EPYC 7003 only
- Linux
- RHEL 8.3-8.10, 9.0-9.8, 10.0-10.2 (EPYC 7002 also RHEL 7.6-7.9, 8.1, 8.2); SLES 12 SP5, 15 SP2-SP7 (SP1 on EPYC 7002), 16; Ubuntu 22.04, 24.04, 26.04 LTS
- VMware
- ESXi 6.7 U3, 7.0 (EPYC 7002) / 7.0 U1-U3, 8.0-8.0 U3, 9.0, 9.1; factory ESXi preload available (not with NVIDIA GPUs)
Processors
- AMD EPYC 7203
- AMD EPYC 7203P
- AMD EPYC 72F3
- AMD EPYC 7303
- AMD EPYC 7303P
- AMD EPYC 7313
- AMD EPYC 7313P
- AMD EPYC 7343
- AMD EPYC 73F3
- AMD EPYC 7413
- AMD EPYC 7443
- AMD EPYC 7443P
- AMD EPYC 7453
- AMD EPYC 74F3
- AMD EPYC 7513
- AMD EPYC 7543
- AMD EPYC 7543P
- AMD EPYC 75F3
- AMD EPYC 7643
- AMD EPYC 7643P
- AMD EPYC 7663
- AMD EPYC 7663P
- AMD EPYC 7713
- AMD EPYC 7713P
- AMD EPYC 7763
- AMD EPYC 7373X
- AMD EPYC 7473X
- AMD EPYC 7573X
- AMD EPYC 7773X
- AMD EPYC 7232P
- AMD EPYC 7252
- AMD EPYC 7262
- AMD EPYC 7F32
- AMD EPYC 7272
- AMD EPYC 7282
- AMD EPYC 7302
- AMD EPYC 7302P
- AMD EPYC 7F52
- AMD EPYC 7352
- AMD EPYC 7402
- AMD EPYC 7402P
- AMD EPYC 7F72
- AMD EPYC 7452
- AMD EPYC 7502
- AMD EPYC 7502P
- AMD EPYC 7532
- AMD EPYC 7542
- AMD EPYC 7552
- AMD EPYC 7642
- AMD EPYC 7662
- AMD EPYC 7702
- AMD EPYC 7702P
- AMD EPYC 7742
- AMD EPYC 7H12