Lenovo's single-socket 1U rack server (machine types 7Y98/7Y99) for one AMD EPYC 7002 "Rome" or 7003 "Milan" processor up to 64 cores and 280 W, with 16 DDR4-3200 DIMM slots (up to 2 TB), up to 16 x 2.5-inch drives (up to 16 NVMe with direct connections) or 4 x 3.5-inch, three rear PCIe 4.0 slots and an OCP 3.0 slot. Aimed at dense NVMe, VDI, inference and software-defined storage nodes where per-socket licensing matters.
Memory
- Slots
- 16 DIMM (8 channels, 2 DIMMs per channel)
- Types
- Lenovo TruDDR4 RDIMM 8, 16, 32, 64 GB and 3DS RDIMM 128 GB, 2933 MHz or 3200 MHz; RDIMM and 3DS RDIMM cannot be mixed; no persistent memory
- Speed
- 3200 MHz DIMMs run at 3200 MHz at 1 DPC and 2933 MHz at 2 DPC; 2933 MHz DIMMs run at 2933 MHz
- Max
- 2 TB (16 x 128 GB 3DS RDIMM); minimum 8 GB
- Population
- For best performance populate 8 or 16 DIMMs so all channels are used; x4 and x8 DIMMs cannot share a channel; at most two DIMM capacities
- Protection
- ECC, SDDC (x4 DIMMs), patrol/demand scrubbing, DRAM address/command parity with replay, uncorrected ECC error retry, Post Package Repair; no mirroring or rank sparing
Storage
- Front 2.5"
- 8 x SAS/SATA, 6 x SAS/SATA + 4 x AnyBay, or 10 x AnyBay (usable as 10 x NVMe without SAS cabling); or no backplane
- Front 3.5"
- 4 x 3.5" SAS/SATA hot-swap
- Mid
- 4 x 2.5" hot-swap NVMe (7 mm drives only) under the top cover; only with the 4 x 3.5" or 10-bay 2.5" front backplanes
- Rear
- 2 x 2.5" hot-swap SAS/SATA or 2 x NVMe (7 mm NVMe only)
- Maximum
- 16 x 2.5" (10 front + 4 mid + 2 rear), up to 16 NVMe with direct x4 connections; 12 SAS/SATA drives
- Controllers
- Onboard SATA (up to 12 drives, no RAID), onboard NVMe (up to 16 drives), RAID 530-8i, 540-8i, 730-8i 1/2 GB, 930-8i/16i, 940-8i/16i (no Tri-Mode), HBA 430-8i/16i, 440-8i/16i
- Internal slot
- Slot 4: internal PCIe 4.0 x8 riser for a RAID adapter or HBA
- M.2 boot
- M.2 module for 1 or 2 drives: SATA RAID kit (Marvell 88SE9230, RAID 0/1) or SATA/NVMe kit (JBOD); 2242/2260/2280
- Optical
- None internal; external USB DVD-RW option
Graphics
- Onboard
- ASPEED AST2500 BMC graphics, max 1920x1200 at 60 Hz
- GPU options
- NVIDIA A2 16GB, T4 16GB, Quadro P620 2GB, up to 3 (slots 1-3)
- Rules
- All GPUs identical; no rear or mid drive bays; no flash adapters; 1100 W (or sometimes 750 W) PSUs; with the intrusion switch only slots 2-3; T4: 2 GPUs max 200 W CPU, 3 GPUs max 120 W CPU and 30 C; P620: CPU max 240 W
Expansion
- Slot 1
- PCIe 4.0 x16, low profile or full-height half-length (riser 1)
- Slot 2
- PCIe 4.0 x16, low profile (riser 2; only in the 3 x LP layout)
- Slot 3
- PCIe 4.0 x16, low profile (riser 2; not with rear drive bays)
- Slot 4
- Internal PCIe 4.0 x8 low profile (physically x16) for a storage controller
- OCP
- Dedicated OCP 3.0 SFF slot, PCIe 4.0 x16
- Slot layouts
- 3 x LP; 1 x FHHL + 1 x LP; 1 x LP + 2 x 2.5" rear drives
Networking
- OCP 3.0
- Optional 2- or 4-port adapters: 1 GbE (Broadcom 5719, Intel I350), 10GBASE-T (Broadcom 57416/57454, Intel X710-T2L/T4L, Marvell QL41132), 10/25 GbE SFP28 (Broadcom 57414/57454/57504, Intel E810-DA2/DA4, Mellanox ConnectX-4 Lx/ConnectX-6 Lx, Marvell QL41232); one port can be shared with the BMC
- PCIe
- 1/10/25 GbE, 100 GbE (Broadcom 57508, ConnectX-6 Dx), InfiniBand HDR100/HDR (ConnectX-6); 100/200 Gb adapters need performance fans
- Fibre Channel
- Emulex LPe35000/35002 32Gb (v1 with EPYC 7002, v2 with EPYC 7003), QLogic QLE2770/2772/2740/2742 32Gb, Emulex and QLogic 16Gb HBAs
- Management
- 1 x RJ-45 1 GbE BMC port
Power
- PSU options
- 550 W, 750 W and 1100 W Platinum (115/230 V), 750 W Titanium (230 V), 1100 W -48 V DC (special bid)
- Redundancy
- 1 or 2 hot-swap PSUs; both must be identical
- Connector
- C14 inlets on AC units; Positronic connector on the -48 V DC unit; 240 V DC input in China only
- Input current
- 100-127 V: 550 W 6.2 A, 750 W 8.4 A, 1100 W 12 A; 200-240 V: 550 W 3.0 A, 750 W 4.1 A, 1100 W 6 A
- Heat output
- 101 W (346 BTU/hr) minimum to 937 W (3197 BTU/hr) maximum configuration
- Cooling
- 7 hot-swap 40 mm dual-rotor fans (6 when there is no M.2, internal slot, mid/rear drives or GPU), N+1; standard or performance fan modules; one fan in each PSU
Ports
- Front
- 2 x USB 3.2 Gen 1 (5 Gbps), optional VGA (disables rear VGA when used)
- Rear
- 2 x USB 3.2 Gen 1, 1 x VGA, 1 x DB-9 serial, 1 x RJ-45 BMC management, NMI button
Physical
- Form factor
- 1U rack
- Dimensions
- 440 mm W x 43 mm H x 755 mm D (17.3 x 1.7 x 29.7 in); 482 mm across the rack flanges; Lenovo Docs gives 778.3 mm depth with latches and PSUs
- Weight
- Maximum 19.2 kg (42.3 lb)
- Machine types
- 7Y98 (1-year warranty), 7Y99 (3-year warranty)
- Environment
- ASHRAE A2 (10-35 C); 225 W+ CPUs, mid/rear drives and 3 GPUs limit ambient to 30 C; A3/A4 only for restricted configurations (155 W max CPU, no NVMe, GPUs or 10 GbE+)
- Acoustics
- Typical 5.9 Bel / 43 dBA operating; GPU-rich up to 8.5 Bel / 69 dBA
- Rails
- Toolless slide rail (optional 1U CMA) or toolless friction rail v2; 610-864 mm between rack posts
Management
- BMC
- ASPEED AST2500 baseboard management controller with web-based ThinkSystem System Manager (TSM); remote KVM (up to 1920x1080) and virtual media are standard
- Interfaces
- IPMI 2.0 (IPMI-over-LAN disabled by default), SNMPv3, Redfish, HTML5 web UI; dedicated 1 GbE management port or NC-SI sharing (10/100 Mb) on OCP adapter port 1
- Software
- XClarity Provisioning Manager Lite (LXPM Lite), XClarity Administrator, XClarity Essentials, XClarity Energy Manager, Capacity Planner
- Security
- TPM 2.0 (Nationz TPM 2.0 in China, CTO only), NIST SP 800-147B, Secure Boot, AMD Secure Root-of-Trust, optional intrusion switch (CTO only) and lockable front bezel, power-on and administrator passwords
- Local
- Front operator panel, pull-out network information tab, light path fault LEDs for DIMMs, drives, fans and PSUs
- Announced
- Product guide first published 2019-08-07
- Withdrawn
- Withdrawn from marketing (Lenovo Press update of 2025-03-12)
Operating systems
- Windows
- Windows Server 2016, 2019, 2022
- Linux
- RHEL 7.6-7.9 (EPYC 7002 only), 8.0-8.10 (8.3 and later with EPYC 7003), 9.0-9.8; SLES 12 SP4 (7002 only) and SP5, 15 SP1 (7002 only) to SP7; Ubuntu 22.04 and 24.04 LTS
- VMware
- ESXi 6.5 U3 (EPYC 7002 only), 6.7 U3, 7.0 and 7.0 U1 (EPYC 7002 only), 7.0 U2, 7.0 U3, 8.0 through 8.0 U3; factory ESXi preload available (not with NVIDIA GPUs)
Processors
- AMD EPYC 7203
- AMD EPYC 7203P
- AMD EPYC 72F3
- AMD EPYC 7303
- AMD EPYC 7303P
- AMD EPYC 7313
- AMD EPYC 7313P
- AMD EPYC 7343
- AMD EPYC 73F3
- AMD EPYC 7413
- AMD EPYC 7443
- AMD EPYC 7443P
- AMD EPYC 7453
- AMD EPYC 74F3
- AMD EPYC 7513
- AMD EPYC 7543
- AMD EPYC 7543P
- AMD EPYC 75F3
- AMD EPYC 7643
- AMD EPYC 7643P
- AMD EPYC 7663
- AMD EPYC 7663P
- AMD EPYC 7713
- AMD EPYC 7713P
- AMD EPYC 7763
- AMD EPYC 7232P
- AMD EPYC 7252
- AMD EPYC 7262
- AMD EPYC 7F32
- AMD EPYC 7272
- AMD EPYC 7282
- AMD EPYC 7302
- AMD EPYC 7302P
- AMD EPYC 7F52
- AMD EPYC 7352
- AMD EPYC 7402
- AMD EPYC 7402P
- AMD EPYC 7F72
- AMD EPYC 7452
- AMD EPYC 7502
- AMD EPYC 7502P
- AMD EPYC 7532
- AMD EPYC 7542
- AMD EPYC 7552
- AMD EPYC 7642
- AMD EPYC 7662
- AMD EPYC 7702
- AMD EPYC 7702P
- AMD EPYC 7742
- AMD EPYC 7H12