Tech Spec Spec it right!

Lenovo ThinkAgile VX665 V3

Lenovo's 2-socket 2U VMware hyperconverged system, code name Kauai (Integrated System MTM 7D9LCTO1WW, Certified Node 7D9LCTO2WW; built on the ThinkSystem SR665 V3), for one or two AMD EPYC 9005 "Turin" or 9004 "Genoa" processors, with 24 DDR5 DIMM slots (up to 6 TB) and up to 40 x 2.5" or 16 x 3.5" drive bays across SAS/SATA/NVMe. Supports up to 8 single-wide or 3 double-wide GPUs and factory-ships VMware ESXi for vSAN clusters via the ThinkAgile VX Deployer.

Memory

Slots
24 DIMM with 2 processors (12 per CPU), 1 DIMM per channel across 12 memory channels per CPU
Max
6 TB using 24 x 256 GB TruDDR5 3DS RDIMM-A
Types
Lenovo TruDDR5 RDIMM, 3DS RDIMM and 9x4 RDIMM, up to 6000 MHz
Protection
ECC, SDDC, Patrol/Demand Scrubbing, Bounded Fault, DRAM Address/Command Parity with Replay, DRAM Uncorrected ECC Error Retry, On-die ECC, ECC Error Check and Scrub (ECS), Post Package Repair
Persistent memory
Not supported

Storage

Drive bays
Up to 20 x 3.5" (8 or 12 front, 4 middle, 2 or 4 rear) or up to 40 x 2.5" (8/16/24 front, 8 middle, 4 or 8 rear) hot-swap bays; combinations of SAS/SATA, NVMe or AnyBay
Boot drives
2 x 7 mm hot-swap rear drives (SATA or NVMe), plus an internal M.2 module for up to 2 M.2 SATA drives, in addition to the main drive bays
Controllers
Onboard NVMe (no RAID); NVMe Retimer Adapter (PCIe 4.0/5.0); 12 Gb SAS/SATA HBA, non-RAID, 8-port or 16-port, PCIe 4.0 or 3.0
Configuration
All-flash or hybrid vSAN OSA, up to 5 disk groups of Cache/Capacity drives; no onboard SATA controller, no SATA HDD support and no SED drive support on the VX665 V3

Graphics

Onboard
G200 graphics with 16 MB memory, 2D hardware accelerator, integrated into the XClarity Controller; max 1920x1200 32bpp at 60 Hz
Single-wide GPU
Up to 5 x NVIDIA L4 24 GB or up to 4 x NVIDIA RTX PRO 4500 Blackwell Server Edition 32 GB PCIe Gen5 passive GPU
Double-wide GPU
Up to 3 x NVIDIA L40S 48 GB, NVIDIA A16 64 GB, NVIDIA RTX PRO 4500 Blackwell Workstation Edition 32 GB (active), or NVIDIA RTX PRO 6000 Blackwell Max-Q Workstation Edition 96 GB (active)

Expansion

Slots
Up to 10 x PCIe rear slots (PCIe 5.0 or 4.0 depending on riser and rear drive bay selection) via 3 riser cards, plus a dedicated OCP slot; use of some slots requires 2 processors
Riser layout
Riser 1 (slots 1-3) and Riser 2 (slots 4-6) install on the system board; Riser 3 (slots 7-8) is cabled to the system board
OCP 3.0
1 x dedicated OCP 3.0 SFF slot, PCIe 5.0 x16, front- or rear-accessible; one port can be shared with XClarity Controller 2 for Wake-on-LAN/NC-SI

Networking

OCP 3.0 adapters
1/10/25 GbE options (Intel I350, Broadcom 5719/57416, Intel X710-T2L/T4L, Broadcom 57414), 1 installed
PCIe adapters
Up to 10 x adapters at 10GBASE-T, 10G, 25G or 100G
Fibre Channel
16/32/64 Gb Emulex and QLogic PCIe HBAs (up to 10), supported for use cases like data migration

Power

PSU options
750 W, 1100 W, 1800 W, 2400 W and 2600 W (80 PLUS Platinum or Titanium), 220 V AC; 750 W and 1100 W also support 110 V; 240 V DC in China only
Redundancy
Up to 2 x hot-swap redundant PSUs; one fan integrated in each PSU
Cooling
Up to 6 x N+1 redundant hot-swap 60 mm fans; optional open-loop water cooling for the processors (Lenovo Processor Neptune Core Module, requires 2 CPUs)

Ports

Front
1 x USB 3.1 Gen 1 (5 Gb/s), 1 x USB 2.0 (also for XCC local management), external diagnostics port, optional VGA
Rear
3 x USB 3.1 Gen 1 (5 Gb/s), 1 x VGA, 1 x RJ-45 1 GbE XCC management port; optional second XCC port (in OCP slot); optional DB-9 serial port (slot 3)
Internal
1 x USB 3.1 Gen 1 (5 Gb/s) for OS/license key purposes

Physical

Form factor
2U rack
Dimensions
445 mm W x 87 mm H x 764 mm D (17.5 x 3.4 x 30.1 in)
Weight
38.8 kg (85.5 lb) maximum
Machine type
7D9L (3-year warranty)

Management

BMC
XClarity Controller 2 (XCC2, ASPEED AST2600); dedicated rear Ethernet port, optional second redundant XCC2 port in the OCP slot; optional XCC Platinum for remote control
Tools
Lenovo XClarity Administrator, XClarity Integrator (VMware Lifecycle Manager), XClarity Energy Manager
Security
Chassis intrusion switch, power-on and administrator passwords, Root of Trust module with TPM 2.0 and Platform Firmware Resiliency; optional lockable front security bezel
Warranty
3-year customer-replaceable-unit and onsite limited warranty, 9x5 next business day; optional service upgrades (4-hour or 2-hour response, 6-hour fix time)
Cluster
Minimum 4 nodes for a VMware Cloud Foundation (VCF) management domain; minimum 3 hosts (2 with a vSAN witness appliance, requires VVF license) and maximum 64 hosts for a VMware vSphere Foundation (VVF) vSAN cluster, requires vSAN 7.0 or later

Operating systems

Hypervisor
VMware ESXi 7.0 U3 (factory-installed), ESXi 8.0 U2, selected via the ThinkAgile VX Deployer tool

Processors

  • AMD EPYC 9015
  • AMD EPYC 9115
  • AMD EPYC 9135
  • AMD EPYC 9175F
  • AMD EPYC 9255
  • AMD EPYC 9275F
  • AMD EPYC 9335
  • AMD EPYC 9355
  • AMD EPYC 9355P
  • AMD EPYC 9365
  • AMD EPYC 9375F
  • AMD EPYC 9455
  • AMD EPYC 9455P
  • AMD EPYC 9475F
  • AMD EPYC 9535
  • AMD EPYC 9555
  • AMD EPYC 9555P
  • AMD EPYC 9565
  • AMD EPYC 9575F
  • AMD EPYC 9645
  • AMD EPYC 9655
  • AMD EPYC 9655P
  • AMD EPYC 9745
  • AMD EPYC 9825
  • AMD EPYC 9845
  • AMD EPYC 9124
  • AMD EPYC 9174F
  • AMD EPYC 9184X
  • AMD EPYC 9224
  • AMD EPYC 9254
  • AMD EPYC 9274F
  • AMD EPYC 9334
  • AMD EPYC 9354
  • AMD EPYC 9354P
  • AMD EPYC 9374F
  • AMD EPYC 9384X
  • AMD EPYC 9454
  • AMD EPYC 9454P
  • AMD EPYC 9474F
  • AMD EPYC 9534
  • AMD EPYC 9554
  • AMD EPYC 9554P
  • AMD EPYC 9634
  • AMD EPYC 9654
  • AMD EPYC 9654P