Memory

Slots
4 DIMM (2 channels, 2 DIMMs per channel)
Type
HPE DDR4 Standard Memory ECC UDIMM, up to 3200 MT/s; no RDIMM, LRDIMM or non-ECC UDIMM
Max
128 GB: 4 x 32 GB UDIMM
Kits
HPE 8 GB 1Rx8 (P43016-B21), 16 GB 1Rx8 (P43019-B21), 32 GB 2Rx8 (P43022-B21), all DDR4-3200 CAS 22 ECC UDIMM
Speed
Xeon E: 3200 MT/s, except 32 GB dual-rank at 2 DIMMs per channel = 2933 MT/s; Pentium G6405: 2666 MT/s (2400 MT/s with 32 GB at 2 DIMMs per channel)
Population
Slots 3-A, 1-B, 4-C, 2-D; do not mix capacities in a channel that holds a 32 GB DIMM
Protection
ECC

Storage

Chassis options
4 LFF non-hot-plug (SATA), 4 LFF hot-plug (SAS/SATA) or 8 SFF hot-plug (SAS/SATA)
Media bays
2 half-height 5.25" bays: bay 1 takes a SATA optical drive, SAS LTO tape drive or USB RDX dock; bay 2 a SATA optical drive or USB RDX dock
Optical
Optional 9.5 mm SATA DVD-ROM (726536-B21) or DVD-RW (726537-B21), needs the Slimline ODD Enablement Kit (P06309-B21); up to 1, on SATA port 5
Tape / RDX
HPE LTO-7 Ultrium 15000 internal (BB873A, 1 max, needs its own E208i-p, not in the 4 LFF non-hot-plug chassis); HPE RDX internal docking station (C8S06A, 1 max)
SATA ports
6 on the system board: ports 1-4 for the drive bays, 5-6 for the media bays or the M.2 SATA kit
M.2
1 M.2 slot on the system board (PCIe 3.0 x2 NVMe or SATA); the slot can instead hold the iLO-M.2-serial module, which carries the one M.2 SSD; needs the PCI fan and baffle kit
M.2 (PCIe card)
HPE Universal SATA 6G AIC HHHL M.2 SSD Enablement Kit (878783-B21): 2 more M.2 SATA SSDs, uses a PCIe slot and 2 SATA ports, 1 kit max
Boot device
HPE NS204i-p x2 Lanes NVMe PCIe3 x8 OS Boot Device (P12965-B21): 2 x 480 GB M.2 NVMe in RAID 1, uses a PCIe slot, UEFI only
Embedded RAID
Intel VROC SATA software RAID 0/1/5/10; disabled by default (SATA AHCI); UEFI only; Windows Server and Linux, not VMware; covers drive bays 1-4 only
Smart Array
E208i-p or P408i-p SR Gen10 (hot-plug chassis only, Mini SAS Cable Kit P06307-B21: 1 for 4 LFF, 2 for 8 SFF); E208e-p or P408e-p external; max 2 Smart Array controllers
Tri-mode
HPE MR216i-p / MR416i-p Gen10 Plus (hot-plug chassis only, cable kit P57104-B21: 1 for 4 LFF, 2 for 8 SFF)
Energy pack
Performance RAID controllers need the HPE 96W Smart Storage Battery (P01366-B21) or Smart Storage Hybrid Capacitor (P02377-B21) plus holder 786710-B21
Max internal
72 TB: 4 x 18 TB LFF HDD; 61.44 TB: 8 x 7.68 TB SFF SATA SSD
SAS speed
Up to SAS 12G; 24G SAS drives run at 12G

Graphics

Integrated
Integrated video, 16 MB, up to 1920 x 1200 at 60 Hz (32 bpp)
Options
No graphics cards listed in the QuickSpecs

Expansion

Slot 1
PCIe 4.0 x16, full height, full length, 75 W (CPU; PCIe 3.0 with a Pentium)
Slot 2
PCIe 3.0 x4 electrical in an x8 connector, 25 W (PCH)
Slot 3
PCIe 3.0 x4 electrical in an x16 connector, 75 W (PCH)
Slot 4
PCIe 3.0 x4 electrical in an x8 connector, full height, half length, 25 W (PCH)
Slot lengths
User guide: slot 2 half length, slot 3 full length; QuickSpecs lists slot 2 full length and slot 3 half length
Cooling
HPE ML30 Gen10 Front PCI Fan and Baffle Kit (P06303-B21) is required in the hot-plug CTO chassis and whenever an M.2 SSD or most PCIe cards are fitted (not needed for the E208e-p or 1GbE NICs)

Networking

Embedded
Broadcom BCM5720 2-port 1GbE BASE-T (NIC 1 doubles as the shared iLO port)
25GbE options
Broadcom BCM57414 2p SFP28, Intel E810-XXVDA2 2p SFP28 (need the PCI fan kit)
10GbE options
Broadcom BCM57416 2p BASE-T, Broadcom BCM57412 2p SFP+, Intel X710-DA2 2p SFP+ (need the PCI fan kit)
1GbE options
Intel I350-T4 4p, Broadcom BCM5719 4p BASE-T

Power

Standard
HPE 350 W non-hot-plug ATX power supply, Gold (92%) or Platinum (94%, P45212-B21, EMEA only)
Redundant
Up to 2 Flex Slot hot-plug for 1+1: 500 W Platinum (865408-B21), 800 W Titanium (865438-B21, 200-240 VAC only)
Redundancy kit
HPE ProLiant ML30 Gen10 Plus 4U RPS Enablement Kit (P45209-B21) required for Flex Slot supplies
Rules
Do not mix two different power supplies
350 W input
100-240 VAC, 47-63 Hz, 6 A; 350 W steady state, 385 W peak
Fans
1 system fan (92 x 32 mm), heatsink fan, optional front PCI fan (92 x 32 mm); non-hot-plug, non-redundant

Ports

Front
1 x USB 3.2 Gen1, 1 x USB 2.0
Rear
4 x USB 3.0, 1 x VGA, 2 x 1GbE RJ45, 1 x dedicated iLO RJ45 (optional), 1 x serial (optional)
Internal
1 x USB 3.2 Gen1
iLO / serial option
HPE DL20/ML30 Gen10 M.2/Dedicated iLO and Serial Port Kit (P06687-B21): dedicated iLO port, serial cable and one M.2 slot on the module
microSD
Optional HPE 32GB microSD RAID 1 USB Boot Drive (P21868-B21)

Physical

Form factor
4U tower; rack mount via HPE ML Gen10 Tower to Rack Conversion Kit (874578-B21, sliding shelf)
Dimensions (H x W x D)
36.83 x 17.50 x 47.50 cm (14.50 x 6.89 x 18.70 in)
Weight
10.1 kg minimum (4 LFF non-hot-plug) to 17.6 kg fully loaded (QuickSpecs); the user guide gives 10.40-19.00 kg
Security
Front bezel key lock, padlock eye, Kensington slot
Operating temperature
10-35 C standard; 5-45 C extended for approved configurations
Acoustics
LpAm 26-29 dBA (pre-configured models, 23 C)

Management

BMC
HPE iLO 5 (standard) with Intelligent Provisioning; iLO Advanced and iLO Advanced Premium Security Edition licences optional
iLO ports
Shared on NIC 1; optional dedicated port with the P06687-B21 module
Software
HPE OneView Standard/Advanced, HPE GreenLake for Compute Ops Management, InfoSight, Smart Update Manager, iLO RESTful API (Redfish), IPMI 2.0
Security
Silicon Root of Trust, UEFI Secure Boot, embedded TPM 2.0 (disabled on China shipments), Intel SGX, Intel TXT
Warranty
3 years parts, 1 year labor, 1 year onsite next business day (3/3/3 in APAC, Japan and PRC)

Operating systems

Support
Certified OS and hypervisors are listed in HPE's Servers Support & Certification Matrices
Intel VROC SATA
Windows Server and Linux; not VMware
VMware boot
ESXi after 7.x will not support SD card / USB as the only boot device; use M.2 or another persistent device

Processors

  • Intel Xeon E-2388G
  • Intel Xeon E-2386G
  • Intel Xeon E-2378G
  • Intel Xeon E-2378
  • Intel Xeon E-2374G
  • Intel Xeon E-2356G
  • Intel Xeon E-2336
  • Intel Xeon E-2334
  • Intel Xeon E-2324G
  • Intel Xeon E-2314
  • Intel Pentium G6405