Tech Spec Spec it right!

Dell PowerEdge XE9785L

A liquid-cooled 3 OU AI accelerator sled for Dell's IR7044/IR7050 Open Rack (ORv3) infrastructure, pairing two AMD EPYC 9005 "Turin" processors with up to eight SXM/OAM-class GPUs (NVIDIA HGX B300, NVIDIA HGX B200, or AMD Instinct MI355X) for large-scale AI training, fine-tuning, and inferencing.

Memory

Slots
24 × DDR5 DIMM (RDIMM only, ECC)
Max
3 TB (24 × 128 GB); 256 GB RDIMMs planned for a future release (up to ~6 TB)
Speed
Up to 6400 MT/s, 1 DIMM per channel
Voltage
1.1 V

Storage

E1.S NVMe (direct)
RI / MU / Enterprise / DC RI, Gen5, 3.84 TB or 7.68 TB
U.2 NVMe SSD
RI Gen4 3.84/7.68/15.36 TB; MU Gen4 6.4 TB
Configuration C01
16 total NVMe bays (4 × E1.S per front zone), no PERC
Configuration C02
16 total NVMe bays (4 × E1.S per front zone × 4 zones), no PERC
Configuration C03
8 total NVMe bays (4 × 2.5" NVMe per zone × 2 zones), no PERC
Boot
Embedded BOSS: hardware RAID 0/1 across 2 × M.2 NVMe SSDs, dedicated heat sinks
RAID/PERC
None — no dedicated PERC or software RAID on this platform

Graphics

Options
8 × NVIDIA HGX B300 NVL8 270 GB 1100 W SXM6 (NVLink); 8 × NVIDIA HGX B200 180 GB 1000 W SXM6 (NVLink); 8 × AMD Instinct MI355X 288 GB 1400 W OAM (AMD Infinity Fabric)
Cooling
Direct liquid cooling (DLC) modules on the GPU tray; not air-cooled at the GPU level

Expansion

PCIe slots
Up to 12 × Gen5 x16, full-height, half-length (no expansion riser — cards install directly)
OCP
1 × OCP NIC 3.0 (slot 13), Gen5 x16, shared LOM / iDRAC port redirect with aux power

Networking

Front I/O
2 × 1 GbE RJ45, dedicated iDRAC Ethernet (failover on the 16×E1.S front-I/O variant)
OCP NIC 3.0 options
2 × 10 GbE, 4 × 10 GbE, 2 × 25 GbE, 4 × 25 GbE, or 2 × 100 GbE (Broadcom, Intel, or NVIDIA cards; some speeds planned for a future release)
PCIe fabric NICs
Up to 12 × Gen5 x16 slots support 400 Gb NICs (AMD, NVIDIA ConnectX-7/OSFP, Broadcom) and OSFP modules for embedded CX-8

Power

Power shelf
21-inch ORv3 power shelf, +50 V output, up to 6 × 5500 W AC Titanium PSUs (33 kW total), hot-swap, N+1
Input
180–350 VAC / 26 A, 47–63 Hz, 80 PLUS Titanium
Monitoring
PMBus (PSU) and MODBUS (PDB/PMC), 1% power-monitoring accuracy

Ports

Front
1 × USB 3.0 Type-A, 1 × USB 2.0 Type-C (iDRAC Direct), 1 × Mini-DisplayPort, 2 × RJ45 dedicated iDRAC Ethernet
Internal
1 × USB 3.0, 1 × internal USB 2.0
Rear
None (all host I/O is on the front I/O board)

Display

Controller
Matrox G200, 16 MB video frame buffer
Max resolution
1920 × 1200 @ 60 Hz

Physical

Sled dimensions (H × W × D)
140.5 mm × 537 mm × 1047.95 mm with fan (889.65 mm without fan)
Weight
94.6–95.4 kg (208.6–210.3 lb) depending on GPU/drive configuration
Chassis
3 OU (1 OU = 48 mm) sled that installs in the IR7044 (44 OU) or IR7050 (50 OU) Open Rack
Handling
Server lift required for loads over 120 lb; 2–3 person lift below that
Acoustics
Category 6 (typical MI355X configuration)
Operating temperature
10°C–35°C (50°F–95°F) ambient, ASHRAE A2; max operating altitude 3050 m

Management

Embedded
iDRAC10 (Datacenter license bundled), iDRAC Direct, RACADM CLI, iDRAC RESTful API with Redfish, iDRAC Service Module
Consoles
OpenManage Enterprise, OME Power Manager, OME Update Manager, OME APEX AIOps Observability, CloudIQ for PowerEdge
Integrations
Red Hat Ansible Modules, Terraform Providers, BMC TrueSight, OpenManage Integration with ServiceNow
Security
Secure Enterprise Key Management (SEKM), Secure Component Verification (SCV), telemetry streaming, System Lockdown

Operating systems

Supported
Canonical Ubuntu Server LTS
Planned
Red Hat Enterprise Linux (listed by Dell as expected in a future release)

Processors

  • AMD EPYC 9965
  • AMD EPYC 9755
  • AMD EPYC 9845
  • AMD EPYC 9825
  • AMD EPYC 9655
  • AMD EPYC 9575F
  • AMD EPYC 9475F
  • AMD EPYC 9455